Validation of a spatial speech-in-speech test that takes signal-to-noise ratio (SNR) confounds into account

Authors

  • Søren Laugesen Eriksholm Research Centre, Oticon A/S, Rørtangvej 20, 3070 Snekkersten, Denmark
  • Filip Marchman Rønne Eriksholm Research Centre, Oticon A/S, Rørtangvej 20, 3070 Snekkersten, Denmark
  • Niels Søgaard Jensen Eriksholm Research Centre, Oticon A/S, Rørtangvej 20, 3070 Snekkersten, Denmark
  • Maria Grube Sorgenfrei Eriksholm Research Centre, Oticon A/S, Rørtangvej 20, 3070 Snekkersten, Denmark

Abstract

A Spatial Fixed-SNR (SFS) speech-in-speech intelligibility test is presented and the reliability and validity of the test is investigated. As part of the validation the SFS test was used to compare a linear hearing-aid setting to a setting with aggressive compression limiting. Two sub-groups of listeners were tested in a fixed-SNR paradigm at –5 and +5 dB SNR, respectively.

References

Naylor, G., Rønne, F.M., and Johannesson, R.B. (2008). “Perceptual correlates of the long-term SNR change caused by fast-acting compression,” International Hearing Aid Research Conference (IHCON), Lake Tahoe, CA, USA (poster).

Naylor, G., and Johannesson, R.B. (2009). “Long-term signal-to-noise ratio at the input and output of amplitude-compression systems,” J. Am. Acad. Audiol., 20, 161-171.

Nielsen, J.B., and Dau, T. (2011). “The Danish hearing in noise test,” Int. J. Aud., 50, 202-208.

Pearsons, K.S., Bernett, R.L., and Fidell, S. (1977). “Speech levels in various noise environments,” Bolt, Beranek and Newman Inc., Canoga Park, California.

Rønne, F.M., Laugesen, S., Jensen, N.S., Hietkamp, R.K., and Pedersen, J.H. (2013), “Magnitude of speech-reception-threshold manipulators for a spatial speech-in-speech test that takes signal-to-noise ratio confounds and ecological validity into account,” Proc. Meet. Acoust., 19, International Congress on Acoustics, Montréal, Canada, pp. 050069.

Smeds, K., Wolters, F., and Rung, M. (2012). “Realistic signal-to-noise ratios,” International Hearing Aid Research Conference (IHCON), Lake Tahoe, CA, USA (poster).

Wagener, K., Josvassen. J.L., and Ardenkjær, R. (2003). “Design, optimization and evaluation of a Danish sentence test in noise,” Int. J. Aud., 42, 10-17.

Additional Files

Published

2013-12-15

How to Cite

Laugesen, S., Rønne, F. M., Jensen, N. S., & Sorgenfrei, M. G. (2013). Validation of a spatial speech-in-speech test that takes signal-to-noise ratio (SNR) confounds into account. Proceedings of the International Symposium on Auditory and Audiological Research, 4, 397–404. Retrieved from https://proceedings.isaar.eu/index.php/isaarproc/article/view/2013-45